温湿度变送器HRT-TH182S
Temperature & Humidity Transmitters

HRT-TH182S Split-Type Temperature & Humidity Transmitter

Split-type temperature and humidity transmitter for applications where the sensing point and transmitter location should be separated. Confirm probe, cable, output, placement and environmental exposure.

Specifications

Product Model
HRT-TH182S (Split-Type / Remote Probe)
Humidity Range
0% to 100% RH
Humidity Accuracy
±3% RH @25°C (Customizable to ±2% RH)
Humidity Annual Drift
≤ ±1% RH / Year
Temperature Range
-40°C to +120°C (Remote Probe)
Temperature Accuracy
±0.5°C @25°C
Dew Point Range
-100°C to +100°C (Accuracy: ±0.5°C)
Response Time
≤ 2 seconds
Power Supply
12 to 24V DC (Working Current: ≤ 50mA)
Signal Output
4-20 mA (2-wire) / RS485 (Modbus-RTU) / 0-5V / 0-10V
Load Resistance
Current Output: ≤ 500 Ω; Voltage Output: Impedance 250 Ω
Ingress Protection
IP66 (Dust-tight and water-jet proof)
Ambient Temp (Body)
-10°C to +70°C
Mounting Formats
Wall-mount, Duct-mount, Split-probe, or other enclosure options by configuration
Customization
Bespoke probe lengths, cables, and enclosures available upon request

What this product is

Split-type temperature and humidity transmitter for applications where the sensing point and transmitter location should be separated. Confirm probe, cable, output, placement and environmental exposure.

Application fit

This temperature or environmental product can be reviewed for process, equipment, HVAC or ambient monitoring when the sensing element, range, placement and interface suit the measurement point.

Selection information required

  • Measured variable, sensor or input type and required range.
  • Probe, lead, insertion, surface or ambient placement requirements.
  • Process connection, output, power, display and enclosure requirements.
  • Condensation, humidity, airflow, contamination, calibration and maintenance conditions.

Installation and integration

Review sensing position, insertion or surface contact, local heat sources, condensation, cable routing, grounding and access for verification. Confirm the selected sensor, transmitter and control-system scaling as one measurement chain.

Verified specifications

Use only specifications confirmed for the exact model and ordered configuration. Unverified numerical ranges, accuracy, materials, protection ratings, certifications, protocols and performance claims are intentionally not stated here.

Limitations and review conditions

Product names or family labels do not by themselves prove hazardous-area approval, waterproofing, corrosion resistance, hygienic suitability, wireless capability or compatibility with a particular medium or control system. Check the exact documentation and configuration before selection.

Next step

Contact our technical team with the medium, range, process conditions, connection, output and installation details to request a configuration review.