HRT-T300 Standard Integrated Temperature Transmitter
HRT-T300 Standard Integrated Temperature Transmitter1
HRT-T300 Standard Integrated Temperature Transmitter3
Process Temperature Transmitters

HRT-T300 Standard Integrated Temperature Transmitter

Integrated temperature-transmitter family without a required local display. Confirm sensing element, probe length/construction, connection, output, enclosure and operating conditions.

Specifications

Sensor Elements
RTD: Pt100, Pt1000; TC: Type K, T, E, S, B
Measuring Range
RTD: -200°C to +600°C; TC: -40°C to +1200°C
Accuracy Class
Class A (±0.15°C); Class B (±0.3°C)
Signal Output
4-20 mA / HART™; Optional 0-5V, 0-10V, RS485 Modbus
Wiring Config
2-wire, 3-wire, or 4-wire (Bespoke)
Process Connection
Thread (M20/G1/2/NPT) or Flange (Customizable)
Protection Rating
IP66 / IP68 (Depending on configuration)
Customization
Probe diameter, insertion depth, and extensions

What this product is

Integrated temperature-transmitter family without a required local display. Confirm sensing element, probe length/construction, connection, output, enclosure and operating conditions.

Application fit

This temperature or environmental product can be reviewed for process, equipment, HVAC or ambient monitoring when the sensing element, range, placement and interface suit the measurement point.

Selection information required

  • Measured variable, sensor or input type and required range.
  • Probe, lead, insertion, surface or ambient placement requirements.
  • Process connection, output, power, display and enclosure requirements.
  • Condensation, humidity, airflow, contamination, calibration and maintenance conditions.

Installation and integration

Review sensing position, insertion or surface contact, local heat sources, condensation, cable routing, grounding and access for verification. Confirm the selected sensor, transmitter and control-system scaling as one measurement chain.

Verified specifications

Use only specifications confirmed for the exact model and ordered configuration. Unverified numerical ranges, accuracy, materials, protection ratings, certifications, protocols and performance claims are intentionally not stated here.

Limitations and review conditions

Product names or family labels do not by themselves prove hazardous-area approval, waterproofing, corrosion resistance, hygienic suitability, wireless capability or compatibility with a particular medium or control system. Check the exact documentation and configuration before selection.

Next step

Contact our technical team with the medium, range, process conditions, connection, output and installation details to request a configuration review.