HRT-T100WP Waterproof Lead RTD Sensor
HRT-T100H Hirschmann-Connector RTD Sensor
RTD Sensors & Thermocouples

HRT-T100WP Waterproof Lead RTD Sensor

Lead-style temperature sensor family for wet or humid installations when the exact sealing, cable, probe and material construction are suitable. Confirm exposure, range and connection before selection.

Specifications

Measuring Range
RTD: -200°C to +600°C; Thermocouple: 0°C to +800°C; confirm any higher or custom range for the exact element and assembly
Process Connection
Available by configuration; confirm the exact lead-style sensor assembly and installation
Ambient Temperature
-20°C to +80°C (For transmitter/junction box electronics)
Reference Accuracy
±0.5°C (Standard)
Junction Box Rating
IP66 / IP67 for the selected junction-box configuration; confirm cable, probe and complete-assembly sealing separately
System Compatibility
Supports various transmitters; Compatible with PLCs, VFDs (Inverters), and Data Recorders
Sensing Elements
RTD: Pt100 or Pt1000; Thermocouple: Type B, E, J, K, N, R, S or T by configuration
Response Time
< 1 second (existing listed value; confirm probe construction and test conditions)
Typical Applications
Application-dependent; confirm medium, temperature, mounting and complete assembly
Technical Note
Bespoke engineering available for non-standard site requirements. Please consult our team for application vetting.

What this product is

Lead-style temperature sensor family for wet or humid installations when the exact sealing, cable, probe and material construction are suitable. Confirm exposure, range and connection before selection.

Application fit

This temperature or environmental product can be reviewed for process, equipment, HVAC or ambient monitoring when the sensing element, range, placement and interface suit the measurement point.

Selection information required

  • Measured variable, sensor or input type and required range.
  • Probe, lead, insertion, surface or ambient placement requirements.
  • Process connection, output, power, display and enclosure requirements.
  • Condensation, humidity, airflow, contamination, calibration and maintenance conditions.

Installation and integration

Review sensing position, insertion or surface contact, local heat sources, condensation, cable routing, grounding and access for verification. Confirm the selected sensor, transmitter and control-system scaling as one measurement chain.

Verified specifications

Use only specifications confirmed for the exact model and ordered configuration. Unverified numerical ranges, accuracy, materials, protection ratings, certifications, protocols and performance claims are intentionally not stated here.

Limitations and review conditions

Product names or family labels do not by themselves prove hazardous-area approval, waterproofing, corrosion resistance, hygienic suitability, wireless capability or compatibility with a particular medium or control system. Check the exact documentation and configuration before selection.

Next step

Contact our technical team with the medium, range, process conditions, connection, output and installation details to request a configuration review.